A binary sensor's tile and card now say what Home Assistant says for its device class, such as Open or Closed for a door and Wet or Dry for a leak sensor. The screen maps the class it already receives, with the same words as the top bar and the history card; a test keeps both tables equal. A history card still waiting for its answer no longer shows the previous card's word. Lights and binary sensors that are off turn grey, as in Home Assistant, and a light without an icon of its own shows a crossed-out bulb while it is off, on the tile and in the top bar. A chosen icon stays and turns grey. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
3.7 KiB
3.7 KiB
Test results app 0.2.62 / firmware 0.2.53 (2026-09-17)
A binary sensor tile read "On" or "Off" where Home Assistant says "Open" or "Closed", and a user (Remco) asked for a different icon for lights that are off. Max asked to do it the way Home Assistant's web interface does. See CHANGELOG 0.2.62 and the compatibility note in docs/RELEASING.md.
Home Assistant's own behaviour
- Source,
devbranch:homeassistant/components/light/icons.jsongivesmdi:lightbulb, andmdi:lightbulb-offfor state off (switch, fan and input_boolean have the same pattern); the frontend colours active lights--state-light-active-color(amber) and anything off--state-inactive-color(grey). - Live on Max's dashboard: lights that are on have an amber icon on a pastel amber circle; lights that are off are grey, with a crossed-out icon where the icon has one; a light with its own icon (a mirror) keeps it and turns grey.
Automated
- Python (
.venv-portal): all tests OK. Newtests/test_binary_words.py(5): the firmware'sBINARY_WORDSequalsheader_bar.BINARY_STATES; the top bar and the history card give the same words for all 28 classes, and On/Off without a class or with an unknown one; every state message already carriesdevice_class(nox); the tile, the card and the history heading use the words for binary sensors only, and the heading only takes its own entity's history words; all five text fonts of both profiles and packages carry every letter. Newtests/test_off_look.py(3):lightbulb-off(F0E4F) in the fonts of both profiles and packages; the firmware's off bulb and grey rule; the top bar's off bulb, a light's own icon kept, no accent while off. - C++ (
clang++ -std=c++17 -Wall -Wextra -Werror -I. -I components/smart_display): 15/15 PASS;test_tile_controlschecks door, motion, moisture, battery charging, battery, no class, an unknown class and a wrongly cased class. generate_packages.py --checkandgenerate_icons.py --check(150 pickable icons, 184 glyphs) green.
Builds (ESPHome 2026.6.2)
Check profiles with the generated packages and local components, as for 0.2.59. No warnings from runtime_tiles.h
or tile_controls.h.
| Profile | RAM | Flash | vs 0.2.59 |
|---|---|---|---|
| CYD | 23.5% (77,060 B) | 77.8% (1,428,127 B) | +0 B RAM, +1,112 B flash (0.2.60 and 0.2.61 included) |
| Guition | 24.5% (80,436 B) | 18.9% (1,531,911 B) | +0 B RAM, +1,580 B flash (0.2.60 and 0.2.61 included) |
Firmware on the Mac (host builds, driven over the ESPHome API)
A demo home with fifteen binary sensors of every kind, lights on and off, and the front door and a light in the top
bar (.esphome/readme-render/binary/), with a probe that logs each card's text and colours:
- Before (0.2.52 code): every binary sensor read On or Off in amber, while the top bar said Open and Motion; the door card said "On" until its history arrived and then "Open"; the motion card opened after the door card said "Open".
- After, Guition and CYD: Open, Closed, Motion, Dry, Smoke, Disconnected, Not charging, Low, Problem, Up to date, Plugged in (also as a large value); a sensor without a class and an unknown class still say On. The door card says "Open" while loading and after the answer, and "Closed" once the door closes with the card open; the motion card says "Motion" while loading. The longest words fit a single CYD tile.
- Off look (Guition): an off light without an icon shows a grey crossed-out bulb, an off light with a chosen lamp icon a grey lamp, a closed door and a dry leak sensor grey circles; the open door, motion and a light at 50 % stay amber; the top bar shows the crossed-out bulb for the off light.
Not tested
- Physical screens: not flashed in this round.