Files
Max Gramser 08197c4ae1 Free memory on the CYD and drop the old manual profile (0.2.50)
The CYD restarted under load: a slider fill rounded less than its track made
LVGL draw the fill into a buffer of its own size on every redraw (15-20 KB), and
when that allocation failed the refresh retried until the task watchdog fired.
Track and fill now share one radius, and tests/test_layer_free.py keeps every
layer-making style out of the profiles, the packages and the firmware headers.

A tile keeps only the fields every card uses; climate modes, select options,
weather, sun and timer times, the media title and the vacuum rows moved to an
Extra block that exists only while a state needs one, and the state copy became
a fingerprint. runtime_tiles::model went from 24,296 to 8,216 bytes.

The manual profile that bound tiles to fixed entities in the YAML is gone:
331 TILE* substitutions, DYNAMIC_TILES/TILE_COUNT/DIRECT_ACTIONS, the 80 Home
Assistant subscriptions, its tap handlers and scripts, its own vacuum card, its
guides and helper scripts, and the five stale header copies in the repository
root that two C++ tests were compiling instead of the components. esphome config
of both Easy profiles is unchanged by that cleanup.

tile_scroll and the wake overlay no longer light up on a tap, and the debug
sensor min_free reports the lowest free heap since boot. On the bench CYD static
RAM went from 32.0% to 22.8% and free heap from 64-77 KB to about 101 KB, with
78 KB as the lowest point over thirteen hours without a restart.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-16 08:06:41 +02:00

87 lines
3.5 KiB
Python

"""Offline regression tests for the guided USB touch calibration."""
import copy
from pathlib import Path
import re
import sys
import tempfile
import unittest
ROOT = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(ROOT / 'tools'))
import calibrate
def measurements():
points = []
for name, (x, y) in calibrate.TARGETS:
rx = round(280 + y * 3580 / 240)
ry = round(340 + x * 3520 / 320)
samples = [dict(raw_x=rx+d, raw_y=ry+d, native_x=239-y,
native_y=x, pressure=1500) for d in (-2, 0, 2)]
points.append(dict(name=name, screen=[x, y], samples=samples))
return dict(schema=1, screen=[320, 240], points=points)
class CalibrationTests(unittest.TestCase):
def test_identity_fit_and_independent_verification(self):
coefficients, report = calibrate.fit(measurements())
self.assertAlmostEqual(coefficients[0], 1, places=3)
self.assertAlmostEqual(coefficients[4], 1, places=3)
self.assertTrue(all(p['error_px'] < 1 for p in report))
self.assertEqual(len(calibrate.verify(measurements())), 5)
def test_affine_skew_is_corrected(self):
data = measurements()
for point in data['points']:
for s in point['samples']:
x, y = s['raw_x'], s['raw_y']
s['raw_x'] = round(.9*x - .03*y + 190)
s['raw_y'] = round(.04*x + .95*y + 50)
_, report = calibrate.fit(data)
self.assertTrue(all(p['error_px'] < 1 for p in report))
def test_center_is_not_used_to_hide_bad_fit(self):
data = measurements()
for s in data['points'][4]['samples']: s['raw_x'] += 600
with self.assertRaisesRegex(ValueError, 'center'): calibrate.fit(data)
def test_jitter_rejected(self):
data = measurements()
data['points'][0]['samples'][0]['raw_x'] += 700
with self.assertRaises(ValueError): calibrate.fit(data)
def test_repeated_corner_rejected(self):
data = measurements()
for p in data['points']: p['samples'] = copy.deepcopy(data['points'][0]['samples'])
with self.assertRaises(ValueError): calibrate.fit(data)
def test_wrong_firmware_coordinates_rejected(self):
data = measurements()
for s in data['points'][0]['samples']: s['native_y'] += 40
with self.assertRaises(ValueError): calibrate.verify(data)
def test_capture_requires_isolated_mode(self):
line = 'press native=20,30 raw=500,600 pressure=1500 calibration='
self.assertEqual(calibrate.parse_touch(line+'1')['raw_x'], 500)
with self.assertRaises(ValueError): calibrate.parse_touch(line+'0')
self.assertIsNone(calibrate.parse_touch('unrelated log'))
def test_wrong_screen_or_order_rejected(self):
for field in ('screen', 'order'):
data = measurements()
if field == 'screen': data['screen'] = [240,320]
else: data['points'].reverse()
with self.assertRaises(ValueError): calibrate.fit(data)
def test_output_requires_explicit_replace_and_preserves_backup(self):
with tempfile.TemporaryDirectory() as tmp:
path = Path(tmp)/'calibration.yaml'
calibrate.write_file(path, 'old')
with self.assertRaises(ValueError): calibrate.write_file(path, 'new')
calibrate.write_file(path, 'new', replace=True)
self.assertEqual(path.read_text(), 'new')
self.assertEqual(next(Path(tmp).glob('*.bak-*')).read_text(), 'old')
if __name__ == '__main__': unittest.main()