Files
homeassistant_espscreen/components/smart_display/__init__.py
T
Xandrossian 4ec8c7a935
CI / checks (push) Waiting to run
CI / firmware (add-on) (push) Blocked by required conditions
CI / firmware (min_version) (push) Blocked by required conditions
Reset the Elecrow's GT911 the way Elecrow's own V3.0 example does (0.2.96, firmware 0.2.82)
The 2 ms reset of ESPHome's expander support (0.2.81) left the chip silent: "Calibration error" with the PCA9557
answering at 0x18. A component of smart_display's (elecrow_touch_reset.h, setup priority 700: after the I2C bus,
before the GT911 driver) writes the expander as Elecrow's V3.0 ESPHome example does: every pin an output and low,
20 ms, the reset released, 100 ms, the interrupt line back to an input. The driver's reset and interrupt pins are gone.
2026-09-21 13:30:41 -07:00

70 lines
3.0 KiB
Python

"""Runtime tile configuration transported through the normal ESPHome API.
`smart_display: language: nl` (app 0.2.90) builds the screen's texts in that language: the `screen` section of
screen_manager/translations/nl.json, with English for any key it lacks, becomes one table in main.cpp
(screen_text_gen.py, screen_text.h). The shared core sets it from the LANGUAGE substitution, which ESP Screens writes
into a screen's YAML.
`smart_display: partitions: 4mb_wide_slots` (firmware 0.2.79) builds with one of the partition tables of partitions.py
instead of ESPHome's own: two update slots of 1,984 KB on a 4 MB ESP32-S3, which the Elecrow CrowPanel 7.0" needs.
`smart_display: elecrow_touch_reset: {i2c_id: ..., address: 0x18}` (firmware 0.2.82) brings the GT911 of the Elecrow
CrowPanel 7.0" V3.0 out of reset through its PCA9557 before the touch driver runs (elecrow_touch_reset.h).
"""
import logging
import esphome.codegen as cg
from esphome.components import esp32, i2c
import esphome.config_validation as cv
from esphome.const import CONF_ID
from esphome.core import CORE
from esphome.helpers import write_file_if_changed
from . import partitions, screen_text_gen
CODEOWNERS = []
AUTO_LOAD = ["json"]
_LOGGER = logging.getLogger(__name__)
CONF_LANGUAGE = "language"
CONF_PARTITIONS = "partitions"
CONF_ELECROW_TOUCH_RESET = "elecrow_touch_reset"
elecrow_ns = cg.global_ns.namespace("elecrow")
TouchReset = elecrow_ns.class_("TouchReset", cg.Component, i2c.I2CDevice)
def _language(value):
value = cv.string_strict(value).strip()
if not screen_text_gen.LANGUAGE_CODE.fullmatch(value):
raise cv.Invalid("Expected a language code such as en, nl or pt-BR")
return value
CONFIG_SCHEMA = cv.Schema({
cv.Optional(CONF_LANGUAGE, default="en"): _language,
cv.Optional(CONF_PARTITIONS): cv.one_of(*partitions.TABLES, lower=True),
cv.Optional(CONF_ELECROW_TOUCH_RESET): cv.Schema({cv.GenerateID(): cv.declare_id(TouchReset)})
.extend(cv.COMPONENT_SCHEMA).extend(i2c.i2c_device_schema(0x18)),
})
async def to_code(config):
wanted = config[CONF_LANGUAGE]
language, code = screen_text_gen.definitions(wanted)
if language != wanted:
# ESP Screens only writes languages it has; a hand-written one it lacks builds in the nearest it does have.
_LOGGER.warning("No translation for %s yet; the screen's texts are in %s", wanted, language)
cg.add_global(cg.RawStatement(code))
if CONF_PARTITIONS in config:
# ESPHome writes no partitions.csv of its own when one is among the extra build files (esp32.copy_files).
table = CORE.relative_build_path("smart_display_partitions.csv")
write_file_if_changed(table, partitions.TABLES[config[CONF_PARTITIONS]])
esp32.add_extra_build_file("partitions.csv", table)
if CONF_ELECROW_TOUCH_RESET in config:
conf = config[CONF_ELECROW_TOUCH_RESET]
reset = cg.new_Pvariable(conf[CONF_ID])
await cg.register_component(reset, conf)
await i2c.register_i2c_device(reset, conf)