5d6651d68b
Since 0.2.20 the manager repeats a layout every 120 s, while the firmware
treated anything older than 95 s (sized for the original 25 s keepalive) as
stale: on a quiet screen every card read "Niet beschikbaar" and the header
"HA niet verbonden" for 25-45 s of each two-minute round, on both boards.
"HA niet verbonden" now follows ESPHome's own api_is_connected(); the feed
watchdog uses the cadence the layout message declares ("keepalive", seconds,
120 s when absent) and tolerates one missed round plus loop slack before
showing "ESP Screens niet actief". The tick redraws once when either flips.
Firmware 0.2.22 for CYD and Guition.
Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
27 lines
627 B
YAML
27 lines
627 B
YAML
name: ESP Screen Manager
|
|
version: "0.2.26"
|
|
slug: esp_screen_manager
|
|
description: Kies tegels voor je CYD en Guition touchscreen, zonder opnieuw flashen.
|
|
url: https://github.com/MaxGramser/homeassistant_espscreen
|
|
arch: [aarch64, amd64]
|
|
startup: application
|
|
boot: auto
|
|
init: false
|
|
homeassistant_api: true
|
|
ingress: true
|
|
ingress_port: 8099
|
|
panel_icon: mdi:monitor-dashboard
|
|
panel_title: ESP Screens
|
|
panel_admin: true
|
|
options: {}
|
|
schema: {}
|
|
|
|
map:
|
|
- homeassistant_config:rw
|
|
uart: true
|
|
usb: true
|
|
# Reproducible compiler/download caches; retain screens.json and user configuration.
|
|
backup_exclude:
|
|
- '*/build/'
|
|
- '*/platformio/'
|