A unit's touch never answered: "touchscreen is marked FAILED: Calibration error" at setup, the GT911 still in reset behind the PCA9557 (I2C 0x18) of the V3.0 board. The board file declares the expander as ESPHome's pca9554 (the same register map) and hands the GT911 driver its reset (IO0) and interrupt (IO1) pins on it, so the driver runs Elecrow's own sequence: reset low with the interrupt line low, reset high, 56 ms, address 0x5D. A V2.0 without the expander boots its GT911 by the pull-up as before. The bus is scanned at boot for the log.
33 lines
882 B
YAML
33 lines
882 B
YAML
name: ESP Screen Manager
|
|
version: "0.2.95"
|
|
slug: esp_screen_manager
|
|
description: Choose tiles for your CYD and Guition touchscreen, without reflashing.
|
|
url: https://gittea.trippedonmy.name/Xandrossian/homeassistant_espscreen
|
|
arch: [aarch64, amd64]
|
|
startup: application
|
|
boot: auto
|
|
homeassistant_api: true
|
|
ingress: true
|
|
ingress_port: 8099
|
|
# Camera images for Guition screens (docs/CAMERA.md): the screens load them from this port on the LAN.
|
|
ports:
|
|
8098/tcp: 8098
|
|
ports_description:
|
|
8098/tcp: Camera images for the screens (keep 8098)
|
|
panel_icon: mdi:monitor-dashboard
|
|
panel_title: ESP Screens
|
|
panel_admin: true
|
|
options: {}
|
|
schema: {}
|
|
|
|
map:
|
|
- homeassistant_config:rw
|
|
uart: true
|
|
usb: true
|
|
# Reproducible compiler/download caches (firmware.py build_env); retain screens.json and user configuration.
|
|
backup_exclude:
|
|
- '*/build/'
|
|
- '*/esphome/'
|
|
- '*/idf/'
|
|
- '*/platformio/'
|